GE Ohmeda-Datex S5 Patient Monitor IBP Pressure Module Datex-EngStrom MN4F 887464-6

Brand Name : GE

Model Number : Ohmeda-Datex S5

MOQ : 1

Price : Negotation

Payment Terms : T/T, Western Union, PayPal

Supply Ability : 1-20 Pieces

Delivery Time : 1-3 Working Days

Packaging Details : Carton Packing

Brand : GE

Model : Ohmeda-Datex S5

Application : Patient Monitor

Warranty : 90 Days

Shipping : All Over The World

Condition : Original

Supply Voltage : 6V, 12V optional

Services : Maintenance and sales

Feature : Professional, reliable, durable

Power Supply : AC and battery

Performance : Excellent

Stock : In stock

Contact Now

GE Datex-Ohmeda S5 IBP Module Features

  • Dual-Channel IBP Monitoring
    Supports up to two invasive blood pressure channels (e.g., ART, CVP, PA), allowing simultaneous measurement of different pressure types.

  • High Accuracy and Sensitivity
    Provides precise pressure readings with high sensitivity for critical care applications.

  • Real-Time Waveform Display
    Displays continuous pressure waveforms on the monitor screen for live clinical assessment.

  • Customizable Labeling
    Pressure channels can be labeled according to clinical need (e.g., ART, CVP, ICP) for easy identification.

  • Compatibility with Standard Transducers
    Supports a wide range of industry-standard disposable or reusable pressure transducers.

  • Zeroing Function
    Includes manual zeroing functionality to calibrate the transducer and ensure accurate measurements.

  • Integrated with S5 Monitor System
    Seamlessly integrates with the GE Datex-Ohmeda S5 monitor, sharing data with central monitoring and record systems.

  • Compact and Modular Design
    Hot-swappable and modular, allowing easy installation, replacement, or service without shutting down the entire system.

  • Pressure Range and Display
    Wide measurement range (typically -50 to +300 mmHg) with configurable units and display scaling.

  • Alarm and Trend Features
    Programmable high/low pressure alarms and long-term trend recording for patient monitoring and analysis.

  • Digital Signal Processing
    Uses advanced DSP for noise reduction and accurate waveform generation.

  • Electrical Isolation for Patient Safety
    Designed with high electrical isolation to protect patients and ensure system reliability.

Precautions for Using GE Datex-Ohmeda S5 IBP Module

  • Use Compatible Pressure Transducers
    Always use transducers that are approved and compatible with the S5 monitor system to ensure accurate readings.

  • Perform Zeroing Before Use
    Always zero the pressure transducer with the stopcock open to air and at the level of the measurement site (e.g., heart level) before taking measurements.

  • Avoid Air Bubbles in the Line
    Ensure the pressure line is free of air bubbles, as they can distort waveforms and lead to inaccurate readings.

  • Secure All Connections
    Make sure all pressure tubing and electrical connections are tight and secure to prevent leaks or signal loss.

  • Label Pressure Channels Correctly
    Always label and confirm the correct pressure type (e.g., ART, CVP, PA) for each channel to avoid clinical misinterpretation.

  • Monitor for Infection Control
    Use sterile techniques when connecting pressure lines to the patient. Replace transducers and tubing according to hospital infection control policy.

  • Do Not Touch Electrical Contacts
    Avoid touching the electrical connectors on the module or cable ends to prevent contamination or electrostatic damage.

  • Check for Module Recognition
    After inserting the IBP module into the S5 monitor, verify that the system recognizes the module and displays the correct parameters.

  • Avoid Excessive Pressure
    Do not apply excessive pressure to the transducer or tubing to prevent equipment damage or patient injury.

  • Use Electrical Isolation Equipment if Required
    If connecting to other devices, ensure proper electrical isolation to maintain patient safety and avoid ground loops.

  • Clean According to Manufacturer Guidelines
    Clean and disinfect the module and cables according to GE’s instructions to maintain hygiene and extend equipment life.

  • Remove Module Properly
    When removing the IBP module, do so gently to avoid damaging the connector pins or internal circuitry.

  • Verify Alarms and Limits
    Always set and verify alarm limits appropriate to the patient’s condition to ensure timely clinical response.

Brand Model Equipment Parts
GE DASH 2500 patient monitor  
DASH 3000 patient monitor DASH module
DASH 4000 patient monitor
DASH 5000 patient monitor
Cardiocap5 patient monitor  
SOLAR8000/I/M patient monitor TRAM/SAM module
Ohemda Trusat Trusignal Pulse Oximeter  
Ohemda Tuffsat Pulse Oximeter  
Responder 3000 Defibrillator  

GE Ohmeda-Datex S5 Patient Monitor IBP Pressure Module Datex-EngStrom MN4F 887464-6

GE Ohmeda-Datex S5 Patient Monitor IBP Pressure Module Datex-EngStrom MN4F 887464-6


Product Tags:

GE Ohmeda-Datex S5 patient monitor module

      

IBP pressure module for Datex-EngStrom

      

MN4F patient monitor module with warranty

      
Quality GE Ohmeda-Datex S5 Patient Monitor IBP Pressure Module Datex-EngStrom MN4F 887464-6 for sale

GE Ohmeda-Datex S5 Patient Monitor IBP Pressure Module Datex-EngStrom MN4F 887464-6 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou YIGU Medical Equipment Service Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)